    In the medical gas system, a gas monitoring alarm system is generally installed. Their function is to provide the equipment management personnel and medical staff with the status parameters of the medical gas system in real time. Once the parameters exceed the normal range, they will send out sound and light alarm signals to give an alarm.

    Oxygen, vacuum suction, and compressed air are the three most important medical gases, which should be installed in general hospitals. The gas source and pipeline supply system should be safe and reliable. The oxygen, vacuum suction, and compressed air pipelines should be divided into two supply lines. The oxygen, vacuum, and compressed air pipelines for the clean operation department must be supplied separately. In the ward building, each floor nurse station is equipped with oxygen, vacuum, compressed air overpressure and underpressure alarm devices.


    Technical Index

    1. Pressure range: positive pressure: 0KPa-999KPa (special requirements can be increased).

    Negative pressure: 0KPa--99KP

    2. Resolution: 1KPa

    3. Accuracy: ±1.5%

    4. Output signal: standard modbus protocol signal

    5. Alarm default value:

    Gas

    Upper limit alarm

    Upper limit warning

    Lower limit warning

    Lower limit alarm

    Positive pressure

    500KPa

    450KPa

    350KPa

    300KPa

    Negative pressure

    -90KPa

    -80KPa

    -40KPa

    -30KPa


    6. Dimensions:

    Gas type

    Dimensions

    Dimension of wall hole

    1 type of gas pressure

    204×40×210

    186×50×192

    2 types of gas pressure

    286×40×210

    268×50×192

    3 types of gas pressure

    368×40×210

    350×50×192

    4 types of gas pressure

    458×40×210

    440×50×192

    5 types of gas pressure

    540×40×210

    520×50×192

    6 types of gas pressure

    614×40×210

    584×50×192

    Special requirements can be increased


    7. Power supply: AC220V 50Hz (can be customized according to customer requirements)


    Function of Master Alarm Panel

    1. The MCU of the controller adopts a high-speed single-chip microcomputer, which has fast calculation speed, high precision and strong reliability. It can quickly process system tasks and ensure the reliability of system operation.

    2. This regional gas pressure monitoring alarm is suitable for monitoring the gas supply pressure status of hospital floors, nurse stations, operating rooms, ICU or laboratory gas pipelines, special gas cylinders, bus bars, gas valve boxes, etc., through digital tubes The display shows the pressure of the monitored gas in real time. The alarm point can be set according to the usage requirements of each parameter, and over-limit alarm is realized to ensure the normal air supply pressure in the area.

    3. This regional gas pressure alarm is equipped with RS-485 communication interface, which can realize the networking with the main alarm box and the system host through the network.